Product Details:
Sterilized | Yes |
Usage | Hospital, Clinical |
Brand | elanor |
Length | 2 Mtr |
Size Applicable | Adult & Child |
Material | Medical Grade PVC |
Product Details:
Model Name/Number | ECN21 |
Brand | ELANOR |
Usage/Application | Nebulization |
Operation Mode | Portable |
Size | Large |
Storage Condition | Standard |
Country of Origin | Made in India |
1.Remove the nebulizer kit from the air tube and disassemble the | |
nebulizer kit. | |
Separate the inhalation attachment and thenebulizer kit,and | |
2) Unplug the air tube from the nebulizer kit. | |
disassemble the nebulizer kit. | |
NOTE: | |
2.Discard any remaining medication in themedication cup. | |
Always hold the air plug when disconnecting the air tube. | |
3) Checkthatthereisnocondensationormoistureremainingintheairtube. | |
3. Wash all the parts of the nebulizing parts in warm water and mild | |
If there is moisture or liquid remaining in the air tube,be sure to follow | detergent,or wash in a dishwasher. |
the procedure below to remove any moisture from within the air tube. | For instructions on how to disinfect the parts, see the following |
0 Make sure that the air tube is still connected to the air connector on the | section. |
compressor. | 4. After cleaning and disinfecting the parts,rinse them |
ii) Turn on the compressor and pump air through the air tube to expel the moisture. | thoroughly with clean water and allow the parts to air |
dry in a clean environment. | |
4) Unplug the air tube from the compressor. | |
&WARNING : | Disinfecting the Parts of the Nebulizing Parts |
Condensation may occur in the air tube.Do not store the air tube while it | Always disinfect the medication cup,mouthpiece and other parts of |
contains condensation or moisture.This could result in infection via | the nebulizing parts after the last treatment of the day.To disinfect the |
bacteria. | parts,use one of the methods described below: |
5) Unplug the device from the power outlet. | A. Use a commercially available disinfectant. Follow the |
instructions provided by the disinfectant manufacturer. | |
B. Parts may be boiled for more than 15 minutes(except for mask). | |
1. Submerge the parts in the cleansing solution for the specified period. | |
2.Remove the parts and discard the solution. | |
3.Rinse the parts with clean hot tap water. | |
11 | 12 |
Additional Information:
Product Details:
Minimum Order Quantity | 2000 Piece |
Patient Type | Adult |
Tube Length | 10 m |
Application | Hospital |
Material | PVC |
Steribility | Sterile |
Weight | 10-50 Grams (g) |
Product Type | Cannula |
Usage | Clinical, Hospital |
Suitable For | Better Breathe |
Package Size | 75 Poly Bag/Carton |
Additional Information:
Product Details:
Minimum Order Quantity | 80000 Piece |
Application | Hospital |
Material | PVC |
Weight | 10-50 Grams (g) |
Product Type | Nasal |
Suitable For | Better Breathe |
Use | For Patient |
Additional Information: